U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC603 Phase Reversal (Three Phase) POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Power Failure PARAMETER: Phase Reversal (Three Phase) 1. Scope. 1.1. Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment is not damaged by phase reversal or a positive physical means is employed to prevent phase reversal. 2. Validation criteria.

The utilization equipment is considered to have passed if the utilization equipment is not damaged and does not cause an unsafe condition when the input phase sequence is reversed for the applicable edition(s) of MIL-STD-704 and as noted in table TAC603-I. A positive physical means to prevent phase sequence reversal may be used to fulfill this requirement. TABLE TAC603-I. MIL-STD-704 phase sequence reversal requirement. 3. Apparatus. The test equipment should be as follows: a. Adjustable AC power supply b. True RMS voltmeter c. Frequency counter 4. Test setup. Configure the test setup as shown in figure TAC603-1.

Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. 5. Compliance test. If a positive physical means is employed to prevent phase sequence reversal, confirm that the phase conductors cannot be reversed. If the phase sequence can be reversed, with the power source off, install the UUT and the stimulation and monitoring equipment into the test setup of figure TAC603-1 (reversed phase sequence of C-B-A). Turn on the power source and adjust the voltage to the nominal steady state 116 Limit 704A 704B 704C 704D 704E 704F Phase Reversal N/A N/A N/A N/A N/A Phase Sequence Reversal Does not Cause Damage