Downloaded from https://www.everyspec.com True RMS Frequency Voltmeter Counter (See Note 4) (See Note 4) See Note 6 See Note 1 (UUT) Adjustable AC 3-Phase A A Unit Under Test MIL-HDBK-704-3 118 B C N B C Power Supply See Note 2 N IF USED 10 cm GND CHASSIS See Note 3 CAUTION Notes: Ground Plane 1. Voltage measurements shall be made within 10 cm of UUT input power terminals. 2. For 3 phase 4 wire equipment, neutral connection to also be made within 10 cm of UUT input power Stimulation & Monitoring terminals. For 3 phase 3 wire equipment, line-to-neutral measurements to be made with neutral connection made to power supply neutral. Equipment (See Note 5) 3. CAUTION:
Verify suitability of power supply NEUTRAL and GROUND connections. 4. CAUTION: Verify suitability of instumentation inputs and/or use appropriate attenuation. 5. Stimulation and Monitoring Equipment are user defined. This functional block shall provide appropriate 6. Phase Rotation is reversed. Phase Reversal Figure TAC603-1 inputs (stimulations) and monitor UUT outputs (e.g.: RPM, signals, data, etc.) FIGURE TAC603-1. Phase reversal.