Downloaded from https://www.everyspec.com MIL-HDBK-704-3 After all test conditions are complete, adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to confirm that the UUT has not suffered damage and is providing specified performance for normal aircraft electrical conditions. TABLE TAC102-II. Test conditions for steady state limits for voltage and frequency.
12 Test Condition Voltage Frequency Balanced Voltages A Nominal Voltage Nominal Frequency B Nominal Voltage NLSS Frequency C Nominal Voltage NHSS Frequency D NLSS Voltage Nominal Frequency E NLSS Voltage NLSS Frequency F NLSS Voltage NHSS Frequency G NHSS Voltage Nominal Frequency H NHSS Voltage NLSS Frequency I NHSS Voltage NHSS Frequency Unbalanced Voltages J Van NLSS Voltage Vbn NLSS Voltage+3.0V Vcn NLSS Voltage+3.0V Nominal Frequency K Van NHSS Voltage Vbn NHSS Voltage-3.0V Vcn NHSS Voltage-3.0V Nominal Frequency