U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC103 Voltage Phase Difference POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Normal PARAMETER: Voltage Phase Difference 1. Scope. 1.1 Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when provided voltages having phase angles within the limits specified in the applicable edition(s) of MIL-STD- 704. 2. Validation criteria.

The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for normal aircraft electrical conditions when provided voltages having phase angles at the limits of the applicable edition(s) of MIL-STD-704 and as noted in table TAC103-I. The utilization equipment must maintain specified performance for a length of time that confirms the utilization equipment can continuously operate and should be not less than thirty (30) minutes for each of the test conditions. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC103-I.

MIL-STD-704 limits for voltage phase difference. 3. Apparatus. The test equipment should be as follows: a. Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Phase angle meter 4. Test setup. Configure the test setup as shown in figure TAC103-1. Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. 5. Compliance test. With the power source off, install the UUT and the stimulation and monitoring equipment into the test setup of figure TAC103-1.

Turn on the power source and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Energize the UUT. Allow sufficient 16 Limit 704A 704B 704C 704D 704E 704F Voltage Phase Difference 116o to 124o 116o to 124o 116o to 124o 116o to 124o 116o to 124o 116o to 124o