Downloaded from https://www.everyspec.com MIL-HDBK-704-3 time for the UUT to warm up. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. For each test condition A and B noted in table TAC103-II, the UUT must remain for a length of time that confirms the utilization equipment can continuously operate with voltage phase differences and should be, not less than thirty (30) minutes. The phase angles are referenced to Van.
At each test condition conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. Record the voltages, frequency, phase angles, time duration at test condition, and the performance of the UUT for each test condition in the data sheet shown in table TAC103-III. Repeat for each mode of operation of the UUT. After all test conditions are complete, adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz.
Adjust the phase angles to Van 0 o , Vbn 120 o , and Vcn 240 o . Conduct a performance test of the UUT according to the utilization equipment performance test procedures to confirm that the UUT has not suffered damage and is providing specified performance for normal aircraft electrical conditions. TABLE TAC103-II. Test conditions for voltage phase difference. 17 Test Condition Voltage Phase Angle Van Voltage Phase Angle Vbn Voltage Phase Angle Vcn A 0o 116o 240o B 0o 124o 240o