Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC104 Voltage Modulation POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Normal PARAMETER: Voltage Modulation 1. Scope. 1.1 Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to voltage modulation as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.
The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for normal aircraft electrical conditions when supplied input power having voltage modulation as specified in the applicable edition(s) of MIL-STD-704 and as noted in table TAC104-I. The utilization equipment must maintain specified performance for a length of time that confirms the utilization equipment can operate continuously when provided power having voltage modulation. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC104-I.
MIL-STD-704 limits for voltage modulation. 1/ For utilization equipment being tested to MIL-STD-704 edition B, C, and D, use MIL-STD- 704E limits. 3. Apparatus. The test equipment should be as follows: a. Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 4. Test setup. Configure the test setup as shown in figure TAC104-1. Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. 20 Limit 704A 1/ 704B 1/ 704C 1/ 704D 704E 704F Voltage Modulation 3.5 V Peak-to- Valley Figure 1 MIL-STD- 704A sideband 0.62 Vrms over the range 400 ! 60 Hz N/A N/A 2.5 Vrms max 2.5 Vrms max