Downloaded from https://www.everyspec.com MIL-HDBK-704-3 5. Compliance test. With the power source off, install the UUT and the stimulation and monitoring equipment into the test setup of figure TAC104-1. Turn on the power source and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Energize the UUT. Allow sufficient time for the UUT to warm up.

Conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions For each test condition A through G noted in table TAC104-II, set the voltage modulation amplitude and frequency of voltage modulation.

The UUT must remain at the test condition for a length of time that confirms the utilization equipment can continuously operate, and should be at least ten (10) minutes at an average steady state voltage of 115 Vrms, at least ten (10) minutes at an average steady state voltage of 109.25 Vrms, and at least ten (10) minutes at an average steady state voltage of 116.75 Vrms. During the test condition, conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions.

Record average voltage, frequency, amplitude of voltage modulation, frequency of voltage modulation, time duration at test condition, and the performance of the UUT for each test condition in the data sheet shown in table TAC104-III. Repeat for each mode of operation of the UUT. After all test conditions are complete, adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz.

Conduct a performance test of the UUT according to the utilization equipment performance test procedures to confirm that the UUT has not suffered damage and is providing specified performance for normal aircraft electrical conditions. TABLE TAC104-II. Test conditions for voltage modulation. 1/ For utilization equipment being tested to MIL-STD-704 edition B, C, and D, use MIL-STD- 704E limits.

21 Test Condition Frequency of Voltage Modulation MIL-STD-704A Amplitude of Voltage Modulation Voltage Peak-to- Valley 1/ MIL-STD-704E & F Amplitude of Voltage Modulation Vrms A 1.0 Hz 0.5 Vp-v 0.375 Vrms B 1.7 Hz 0.5 Vp-v 0.375 Vrms C 10 Hz 3.5 Vp-v 2.5 Vrms D 25 Hz 3.5 Vp-v 2.5 Vrms E 70 Hz 0.5 Vp-v 0.375 Vrms F 100 Hz 0.5 Vp-v 0.375 Vrms G 200 Hz 0.5 Vp-v 0.375 Vrms