U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC105 Frequency Modulation POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Normal PARAMETER: Frequency Modulation 1. Scope. 1.1. Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to frequency modulation as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.

The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for normal aircraft electrical conditions when supplied input power having frequency modulation as specified in the applicable edition(s) of MIL-STD-704 and as noted in table TAC105-I. The utilization equipment must maintain specified performance for a length of time that confirms the utilization equipment can operate continuously when provided power having frequency modulation. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC105-I.

MIL-STD-704 limits for frequency modulation. 3. Apparatus. The test equipment should be as follows: a. Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 4. Test setup. Configure the test setup as shown in figure TAC105-1. Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. 5. Compliance test. With the power source off, install the UUT and the stimulation and monitoring equipment into the test setup of figure TAC105-1. Turn on the power source and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz.

Energize the UUT. Allow sufficient 26 Limit 704A 704B 704C 704D 704E 704F Frequency Modulation ! 4 Hz ! 5 Hz Figure 3 MIL-STD- 704B ! 5 Hz Figure 4 MIL-STD- 704C ! 5 Hz Figure 4 MIL-STD- 704D 4 Hz 4 Hz