Downloaded from https://www.everyspec.com Oscilloscope True RMS Frequency (See Note 4) (See Note 4) (See Note 4) Voltmeter Counter See Note 1 (UUT) Programmable A A B Unit Under Test MIL-HDBK-704-3 AC 3-Phase Power Supply N See Note 2 C N 29 IF USED CHASSIS See Note 3 10 cm GND CAUTION Ground Plane Notes: 1. Voltage measurements shall be made within 10 cm of UUT input power terminals. Stimulation & Monitoring 2. For 3 phase 4 wire equipment, neutral connection to also be made within 10 cm of UUT input power terminals. For 3 phase 3 wire equipment, line-to-neutral measurements to be made with neutral connection made to power supply neutral. Equipment (See Note 5) 3. CAUTION:
Verify suitability of power supply NEUTRAL and GROUND connections. 4. CAUTION: Verify suitability of instumentation inputs and/or use appropriate attenuation. Frequency Modulation 5. Stimulation and Monitoring Equipment are user defined. This functional Figure TAC105-1 block shall provide appropriate inputs (stimulations) and monitor UUT outputs (e.g.: RPM, signals, data, etc.) FIGURE TAC105-1. Frequency modulation. B C