Downloaded from https://www.everyspec.com MIL-HDBK-704-3 test condition, and the performance of the UUT for each test condition in the data sheet shown in table TAC105-III. Repeat for each mode of operation of the UUT. After all test conditions are complete, adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to confirm that the UUT has not suffered damage and is providing specified performance for normal aircraft electrical conditions. TABLE TAC105-II.
Test conditions for frequency modulation. 28 Test Condition Rate of change for frequency modulation MIL-STD-704 A Amplitude of Frequency Modulation MIL-STD-704 B, C, & D Amplitude of Frequency Modulation MIL-STD-704 E &F Amplitude of Frequency Modulation A 1 Hz/sec ! 4 Hz ! 5.00 Hz 4 Hz (! 2 Hz) B 5 Hz/sec ! 4 Hz ! 1.75 Hz 4 Hz (! 2 Hz) C 10 Hz/sec ! 4 Hz ! 1.20 Hz 4 Hz (! 2 Hz) D 25 Hz/sec ! 4 Hz ! 0.85 Hz 4 Hz (! 2 Hz) E 100 Hz/sec N/A ! 0.58 Hz 4 Hz (! 2 Hz)