Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC106 Voltage Distortion Spectrum POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Normal PARAMETER: Voltage Distortion Spectrum 1. Scope. 1.1 Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to voltage distortion of frequencies and amplitudes as specified by the voltage distortion spectrum in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.
The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for normal aircraft electrical conditions when subjected to voltage distortions as specified by the voltage distortion spectrum in the applicable edition(s) of MIL-STD-704 and as noted in table TAC106-I. The utilization equipment must maintain specified performance for a length of time that confirms the utilization equipment can operate continuously when provided power having voltage distortion. The utilization equipment must not suffer damage or cause an unsafe condition. Note:
This test method subjects the UUT to voltage distortion having frequencies components from 50 Hz to 10 kHz. These voltage distortions simulate voltage distortions within aircraft due to the cumulative effects of generators, electrical distribution systems equipments, and aircraft loads. MIL-STD-461, (Requirements For The Control of Electromagnetic Interference Characteristics of Subsystems and Equipment), Test Method CS101, (Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz) is a complimentary test. Power levels of the voltage distortions differ for the two test methods.
Performance of Test Method TAC106 of this handbook does not relinquish the requirement to perform Test Method CS101 of MIL-STD-461, and performance of Method CS101 of MIL-STD-461 does not relinquish the requirement to perform Test Method TAC106 of this handbook. TABLE TAC106-I. MIL-STD-704 limits for voltage distortion spectrum. 1/ For utilization equipment being tested to MIL-STD-704 edition A, use MIL-STD-704B limits. 33 Limit 1/ 704A 704B 704C 704D 704E 704F Voltage Distortion Spectrum Individual Harmonic Figure 2 MIL-STD- 704B Figure 3 MIL-STD- 704C Figure 3 MIL-STD- 704D Figure 3 MIL-STD- 704E Figure 7 MIL-STD- 704F