Downloaded from https://www.everyspec.com MIL-HDBK-704-3 3. Apparatus. The test equipment should be as follows: a. Adjustable AC power supply b. Variable frequency power source c. Coupling transformer d. True RMS voltmeter e. Frequency counter f. Spectrum analyzer g. (3) Inductors, 50 µH h. (3) Capacitors, 10 µF i. Resistor, calibrated load 4. Test setup. Configure the test setup as shown in figure TAC106-1. Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. 4.1 Calibration (50 Hz to 10 kHz). Install a calibrated resistive load in the test setup shown in figure TAC106-1 in place of the UUT.
The calibrated resistive load should be sized to draw the same current as the UUT. Turn on the adjustable AC power supply and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Set the variable frequency power source to output a sine wave and adjust the frequency and amplitude so that the voltage distortion measured at the input to the calibrated resistive load conforms to each test condition A through H in table TAC106-II. Record the settings of the variable frequency power source for each test condition. 5. Compliance test.
With the adjustable AC power supply off, install the UUT and the stimulation and monitoring equipment into the test setup of figure TAC106-1. Figure TAC106-1 shows the coupling transformer installed in phase A. The test will be repeated with the coupling transformer installed in Phase B and Phase C. Turn on the adjustable AC power supply and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Energize the UUT. Allow sufficient time for the UUT to warm up.
Conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. Set the variable frequency power source to the settings recorded for test condition A of the calibration procedure. For each test condition, remain for a length of time that confirms the utilization equipment can continuously operate with the voltage distortion and should be, not less than five (5) minutes.
At each test condition, conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. After each test condition, monitor the voltage distortion frequency and amplitude while slowly increasing the variable frequency power source frequency and adjusting the amplitude until the next test condition is reached. Do not exceed the voltage distortion spectrum limits. Repeat for each test condition A through H noted in table TAC106-II.
For each test condition, record the phase tested, voltage, frequency, frequency of voltage distortion, amplitude of voltage distortion, time duration at test 34