Downloaded from https://www.everyspec.com MIL-HDBK-704-3 condition, and the performance of the UUT in the data sheet shown in table TAC106-III. Repeat for each mode of operation of the UUT. Turn the adjustable AC power supply off, install the coupling transformer in phase B, adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and the frequency to the nominal steady state frequency of 400 Hz and repeat the testing for phase B.

Turn the adjustable AC power supply off, install the coupling transformer in phase C, adjust the voltage to the nominal steady state voltage of 115 Vrms (line- to-neutral) and the frequency to the nominal steady state frequency of 400 Hz and repeat the testing for Phase C. After all test conditions are complete for Phase A, Phase B, and Phase C, turn the adjustable AC power supply off and remove the coupling transformer from the circuit. Turn on the adjustable AC power supply. Adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to- neutral) and the frequency to the nominal steady state frequency of 400 Hz. Energize the UUT. Allow sufficient time for the UUT to warm up.

Conduct a performance test of the UUT according to the utilization equipment performance test procedures to confirm that the UUT has not suffered damage and is providing specified performance for normal aircraft electrical conditions. TABLE TAC106-II. Test conditions for voltage distortion spectrum. 1/ For utilization equipment being tested to MIL-STD-704 edition A, use MIL-STD-704B limits. 35 Test Condition Frequency of Voltage Distortion MIL-STD-704B 1 C, D, E & F / Amplitude of Voltage Distortion Voltage rms A 50 Hz 0.316 Vrms B 100 Hz 0.316 Vrms C 500 Hz 1.580 Vrms D 1 kHz 3.160 Vrms E 2 kHz 3.160 Vrms F 3 kHz 3.160 Vrms G 5 kHz 1.900 Vrms H 10 kHz 0.950 Vrms