U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 test condition A as noted in table TAC108-II. Turn on the power source and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Energize the UUT. Allow sufficient time for the UUT to warm up. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions.

The UUT must remain for a length of time that confirms the utilization equipment can continuously operate with the direct current component of the AC voltage and should be, not less than thirty (30) minutes. Repeat the test for test condition B as noted in table TAC108-II. Record the voltages, frequency, DC voltage component, time duration at test condition, and the performance of the UUT for each test condition in the data sheet shown in table TAC108-III. Repeat for each mode of operation of the UUT. After all test conditions are complete, set the programmable power supply to produce voltage sine waves without a DC component.

Adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to confirm that the UUT has not suffered damage and is providing specified performance for normal aircraft electrical conditions. TABLE TAC108-II. Test conditions for direct current component of AC voltage. 45 Test Condition MIL-STD-704A, B C, D, E & F Direct Current Component of AC Voltage A + 0.10V B " 0.10 V