U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC109 Normal Voltage Transients POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Normal PARAMETER: Normal Voltage Transients 1. Scope. 1.1 Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to normal voltage transients as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.

The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for normal aircraft electrical conditions when subjected to voltage transients within the normal limits of the applicable edition(s) of MIL-STD-704 and as noted in table TAC109-I. The utilization equipment must maintain specified performance during and after the voltage transients. The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC109-I. MIL-STD-704 limits for normal voltage transients. 3. Apparatus: The test equipment should be as follows: a.

Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 4. Test setup. Configure the test setup as shown in figure TAC109-1. Measurements, except current, must be made within 10 cm of the input power terminals of the UUT. 48 Limit 704A 704B 704C 704D 704E 704F Normal Voltage Transients Figure 3 MIL-STD- 704A Locus of Equivalent Step Function Curves 2 and 3 Figure 4 MIL-STD- 704B Figure 5 MIL-STD- 704C Figure 5 MIL-STD- 704D Figure 4 MIL-STD- 704E Figure 3 MIL-STD- 704F