Downloaded from https://www.everyspec.com MIL-HDBK-704-3 5. Compliance test. With the power source off, install the UUT and the stimulation and monitoring equipment into the test setup of figure TAC109-1. Turn on the power source and adjust the voltage to the nominal steady state voltage of 115 Vrms (line-to-neutral) and adjust the frequency to the nominal steady state frequency of 400 Hz. Energize the UUT. Allow sufficient time for the UUT to warm up. Conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. 5.1 Compliance test for MIL-STD-704A.
The UUT must be subjected to the voltage transients for each test condition A through O noted in table TAC109-II. The voltage must increase or decrease from steady state voltage to the voltage transient level within Ѕ cycle (1.25 milliseconds). The voltage must remain at the voltage transient level for the duration noted in table TAC109-II. The voltage must return to steady state over the time duration noted in table TAC109-II. For test condition G, three over-voltage transients of 160 Vrms for 25 milliseconds are performed, separated by 0.5 seconds. For test condition N, three under-voltage transients of 58 Vrms for 25 milliseconds are performed, separated by 0.5 seconds.
For test condition O, an under-voltage transient of 58 Vrms for 25 milliseconds is immediately followed by an overvoltage transient of 160 Vrms for 25 milliseconds and the voltage returns to steady state over the time duration noted. For each test condition, monitor the performance of the UUT during the voltage transient according to the equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. Repeat each test condition 5 times.
After the power returns to normal steady state limits, conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. Record the steady state voltages, steady state frequency, voltage transient level, time duration at voltage transient, oscilloscope trace, and the performance of the UUT for each test condition in the data sheet shown in table TAC109-IV. Repeat for each mode of operation of the UUT. In addition, for MIL-STD-704A test compliance perform the repetitive normal voltage transient test described later.
5.2 Compliance test for MIL-STD-704B, C, D, E, & F. The UUT must be subjected to the voltage transients for each test condition AA through MM noted in table TAC109-III. The voltage must increase or decrease from steady state voltage to the voltage transient level within Ѕ cycle (1.25 milliseconds). The voltage must remain at the voltage transient level for the duration noted in table TAC109-III. The voltage must return to steady state over the time duration noted in table TAC109-III. For test condition GG, three overvoltage transients of 180 Vrms for 10 milliseconds are performed, separated by 0.5 seconds.
For test condition LL, three undervoltage transients of 80 Vrms for 10 milliseconds are performed, separated by 0.5 seconds. For test condition MM, an undervoltage transient of 80 Vrms for 10 milliseconds is immediately followed by an overvoltage transient of 180 Vrms for 10 milliseconds and the voltage returns to steady state over the time duration noted. For each test condition, monitor the performance of the UUT during the voltage transient according to the equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft electrical conditions. Repeat each test condition 5 times.
After the power returns to normal steady state limits, conduct a performance test of the UUT according to the utilization equipment performance test procedures to verify that the UUT is providing specified performance for normal aircraft 49