U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 TABLE TAC109-III. Test conditions for MIL-STD-704B, C, D, E, and F normal voltage transients.

52 Test Condition Time From Steady State Voltage to Voltage Transient Level milliseconds Voltage Transient Level Vrms Duration at Voltage Transient Level milliseconds Time From Voltage Transient Level to Steady State Voltage milliseconds Overvoltage Transients AA 140 Vrms 60 msec BB 140 Vrms 60 msec 25 msec CC 160 Vrms 34 msec DD 160 Vrms 34 msec 52 msec EE 180 Vrms 10 msec FF 180 Vrms 10 msec 77 msec GG 180 Vrms (3 times) 10 msec every 0.5 sec Undervoltage Transients HH 90 Vrms 35 msec II 90 Vrms 35 msec 45 msec JJ 80 Vrms 10 msec KK 80 Vrms 10 msec 70 msec LL 80 Vrms (3 times) 10 msec every 0.5 sec Combined Transient MM 80 Vrms 180 Vrms 10 msec 10 msec