U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 TABLE TAC109-II. Test conditions for MIL-STD-704A normal voltage transients.

51 Test Condition Time From Steady State Voltage to Voltage Transient Level milliseconds Voltage Transient Level Vrms Duration at Voltage Transient Level milliseconds Time From Voltage Transient Level to Steady State Voltage milliseconds Overvoltage Transients A 135 Vrms 210 msec B 135 Vrms 145 msec 130 msec C 145 Vrms 130 msec D 145 Vrms 90 msec 80 msec E 160 Vrms 48 msec F 160 Vrms 30 msec 40 msec G 160 Vrms (3 times) 25 msec every 0.5 sec Undervoltage Transients H 90 Vrms 300 msec I 90 Vrms 210 msec 180 msec J 70 Vrms 140 msec K 70 Vrms 95 msec 85 msec L 58 Vrms 48 msec M 58 Vrms 30 msec 40 msec N 58 Vrms (3 times) 25 msec every 0.5 sec Combined Transient O 58 Vrms 160 Vrms 25 msec 25 msec