U.S. Department of Defense MIL-HDBK-704-3 — NOT MEASUREMENT

Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC302 Abnormal Voltage Transients POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Abnormal PARAMETER: Abnormal Voltage Transients 1. Scope. 1.1. Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to abnormal voltage transients as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.

The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for abnormal aircraft electrical conditions when subjected to voltage transients within the abnormal limits of the applicable edition(s) of MIL-STD-704 and as noted in table TAC302-I. Unless otherwise specified in the utilization equipment performance specification document, the utilization equipment must automatically return to the performance specified for normal aircraft electrical conditions when the power returns to within normal limits.

The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC302-I. MIL-STD-704 limits for abnormal voltage transients. 3. Apparatus. The test equipment should be as follows: a. Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 4. Test setup. Configure the test setup as shown in figure TAC302-1. Measurements, except current, must be made within 10 cm of the input power terminals of the UUT.

83 Limit 704A 704B 704C 704D 704E 704F Abnormal Voltage Transients Figure 3 MIL-STD- 704A Locus of Equivalent Step Function Curves 1 and 4 Figure 5 MIL-STD- 704B Figure 7 MIL-STD- 704C Figure 7 MIL-STD- 704D Figure 6 MIL-STD- 704E Figure 4 MIL-STD- 704F