Downloaded from https://www.everyspec.com MIL-HDBK-704-3 procedures to verify that the UUT automatically returns to specified performance for normal aircraft electrical conditions when the power returns to within normal limits, and has not suffered damage. Record the steady state voltages, steady state frequency, voltage transient level, time duration at voltage transient, oscilloscope trace, and the performance of the UUT for each test condition in the data sheet shown in table TAC302-V. Repeat for each mode of operation of the UUT. TABLE TAC302-II. Test conditions for MIL-STD-704A abnormal voltage transients.
85 Test Condition Time From Steady State Voltage to Voltage Transient Level milliseconds Voltage Transient Level Vrms Duration at Voltage Transient Level milliseconds Time From Voltage Transient Level to Steady State Voltage milliseconds Overvoltage Transients A 140 Vrms 1450 msec B 140 Vrms 1025 msec 850 msec C 160 Vrms 520 msec D 160 Vrms 390 msec 250 msec E 180 Vrms 98 msec F 180 Vrms 75 msec 50 msec G 180 Vrms (3 times) 20 msec every 0.5 sec Undervoltage Transients H 85 Vrms 1450 msec I 85 Vrms 1025 msec 850 msec J 75 Vrms 520 msec K 75 Vrms 390 msec 250 msec L 45 Vrms 98 msec M 45 Vrms 75 msec 50 msec N 45 Vrms (3 times) 20 msec every 0.5 sec Combined Transient O 45 Vrms 180 Vrms 20 msec 75 msec