Downloaded from https://www.everyspec.com MIL-HDBK-704-3 METHOD TAC303 Abnormal Frequency Transients POWER GROUP: Three Phase, 400 Hz, 115 V AIRCRAFT ELECTRICAL OPERATING CONDITION: Abnormal PARAMETER: Abnormal Frequency Transients 1. Scope. 1.1. Purpose. This test procedure is used to verify that three phase, 115 Volt, 400 Hz power utilization equipment operates and maintains specified performance when subjected to abnormal frequency transients as specified in the applicable edition(s) of MIL-STD-704. 2. Validation criteria.
The utilization equipment is considered to have passed if the utilization equipment operates and maintains performance as specified in the utilization equipment performance specification document for abnormal aircraft electrical conditions when subjected to frequency transients within the abnormal limits of the applicable edition(s) of MIL-STD-704 and as noted in table TAC303-I. Unless otherwise specified in the utilization equipment performance specification document, the utilization equipment must automatically return to the performance specified for normal aircraft electrical conditions when the power returns to within normal limits.
The utilization equipment must not suffer damage or cause an unsafe condition. TABLE TAC303-I. MIL-STD-704 limits for abnormal frequency transients. 3. Apparatus. The test equipment should be as follows: a. Programmable AC power supply b. True RMS voltmeter c. Frequency counter d. Oscilloscope 95 Limit 704A 704B 704C 704D 704E 704F Abnormal Frequency Transients Figure 5 MIL-STD- 704A Locus of Equivalent Step Function Curves 1 and 4 ¶ 5.1.5 MIL-STD- 704B Figure 8 MIL-STD- 704C Figure 8 MIL-STD- 704D Figure 7 MIL-STD- 704E Figure 6 MIL-STD- 704F Abnormal Maximum Rate of Change of Frequency 500 Hz/sec 500 Hz/sec 500 Hz/sec N/A N/A N/A