Downloaded from https://www.everyspec.com FM 1-509 25. Position the face of the swaging tool against the location mark on the tube. The outer edge of the latch must fall within the location mark. Tube insertion must be as shown in Figure 2-9. 26. Set the selector valve to the appropriate hydraulic output. 27. Actuate the swaging tool with 5,250- to 5,750-psi hydraulic pressure. If the shop air input is not available, use the hand pump. 2-14