everyspec.com hydraulic manual — Chapter 2 - Pneudraulic Lines

Downloaded from https://www.everyspec.com FM 1-509 2 8 . Set the selector valve to EXHAUST to relieve the pressure completely. 2 9 . Slide open the latch and remove the swaging tool from the swaged joint. NOTE : Swaging dies make ridges on swaged fitting. Check after-swage dimensions between ridges. 30. Inspect the swaged end with the appropriate size go/no-go inspection gage according to the illustration in Figure 2-10. The fitting may be reswaged only steps 24 through 30). once if the gage does not fit (repeat 31. If the swaging operation was done off the aircraft, position and attach the separable fitting to the component. Align the mating ends and position the union fitting.

Torque the fitting to its final torque; ensure the fixed portion of the fitting is held stationary. 32. With the union fitting positioned correctly, repeat steps 21 through 28 for both ends of the fitting. 2-15