Downloaded from https://www.everyspec.com FM 1-509 Flaring. The flaring tool used by the Army produces tubing flares with 74° angles. It produces a double-lap flare on 3/16- through 3/4-inch mild aluminum tubing and a single-lap flare on all grades of aircraft tubing, including l/8-through 3/4-inch corrosion-resistant steel. When making flares, use the operating instructions furnished with the tool. Single-flared tubing is used for tubing joints on all sizes of steel tubing, 6061 aluminum alloy tubing, and 5052 aluminum alloy tubing with -- more than a l/2-inch outside diameter.
Double-flared tubing is used for tubing joints on all sizes of 5052 aluminum alloy tubing with an outside diameter of 1/2 inch or less. Double flares are less apt to be cut by overtightening, and the tube assembly is less likely to fail under operating pressure. Refer to TM 55-1500-204-25/1 for more detailed information on bending and flaring tubing. Installation. Rigid Tube Assemblies. Before installing a rigid tube assembly in an aircraft, inspect it carefully and remove dents and scratches, if possible, without weakening the tube. Install the proper nuts and sleeves, and obtain a proper fit where the tubing is flared.
Pressure-test the tube assembly to twice its operating pressure before installation. Ensure that the rigid tube assembly is clean and free of all foreign matter. Hand-screw the nuts to the mating connector, and then tighten therewith the proper wrench. Never use pliers. Avoid pulling the rigid tube assembly into place with the nut; line it up before tightening. Install rigid tubing that runs through cutouts with care so that it will not be scarred when it is worked through the hole. When the tubing assembly is long, tape the edges of any cutouts before installing the tubing. Flared Tube Assemblies.
After installing an aluminum alloy tube assembly and tightening to the required torque, check for leaks. If it leaks, do not tighten it any further. Overtightening can badly damage or completely cut off the tubing flare or damage the sleeve or nut. assembly is overtightened, disassemble the leaking connection and correct the fault. Undertightening connections can also be serious; it can cause the tubing to leak at the connector because of the insufficient grip on the flare by the sleeve. In this case, use a torque wrench to prevent undertightening. A nut should never be tightened when pressure is in the line; this could damage the connection without adding any appreciable torque.
Common faults that cause leaking are-- The flare is distorted into the nut threads. The sleeve is cracked. The flare is out of round. The flare is cracked or split. The inside of the flare is rough or scratched. 2-16