everyspec.com hydraulic manual — Chapter 2 - Pneudraulic Lines

Downloaded from https://www.everyspec.com FM 1-509 The connector mating surface is rough or scratched. The connector threads or nuts are dirty, damaged, or broken. If a steel tube assembly leaks, it may be tightened one-sixth of a turn beyond the normal torque to stop the leakage. If the assembly still leaks, it must be disassembled and repaired. Flareless Tube Assemblies. When installing flareless tube assemblies, inspect them to ensure that they have no scratches or nicks and that the sleeve is properly preset. Lubricate the threads of the nuts and connectors with hydraulic fluid.

Place the assembly in the proper position in the aircraft and finger-tighten clamps, brackets, supports, and nuts. The tubing ends should fit snugly in the connectors; little pressure should be required to hold them in place. Tighten the nut by hand until you feel an increase in resistance to turning. If running the nut down with the fingers is impossible, use a wrench, but be alert for the first signs of bottoming. It is important that the final tightening start at the point where the nut just begins to bottom. With a wrench, turn the nut one-sixth of a turn (one flat on a hex nut). Use a wrench on the connector to stop it from turning while tightening the nut.

Flareless tube fittings have no specific torque setting; therefore, use care when finding the exact point where the nut begins to bottom and when applying the required amount of turn on the nut. After the tube assembly is installed, pressure-test the system. If a connection leaks, tighten the nut an additional one-sixth of a turn (making a total of one-third turn). If the connection still leaks after tightening the nut a total of one-third turn, remove the assembly. After removal, inspect the components of the assembly for scores, cracks, foreign material, or damage from overtightening. Overtightening a flareless tube nut drives the cutting edge of the sleeve deeply into the tube.

This causes the tube to be weakened to the point where normal in-flight vibration could cause the tube to shear. After inspection (if no faults are found), reassemble the connections and repeat the pressure-test procedures. Do not in any case tighten the nut beyond one-third of a turn (two flats on the tightened without tube. hex nut); this is the maximum the fitting may be the possibility of permanently damaging the sleeve and FLEXIBLE HOSE Hose is used when flexibility is required in the connections between moving parts and where a line is subject to vibration. The hose is made of a flexible, leakproof inner tube and one or more layers of metal or fabric reinforcement braid.

Rubber or teflon is used for making the flexible inner tubes. The type of material used for the reinforcement braid and the number of layers needed depend mostly on the pressure range of the hose. Medium and high pressure are the two range classifications in aircraft hydraulics. The medium range includes operating pressures of 1,500 psi and below; the high range includes pressures up to 3,000 psi. 2-17