FM 1-509 Downloaded from https://www.everyspec.com valve is set to open if the pressure drop exceeds 50 psi; for example, if the pressure at the filter inlet port was 70 psi, and the pressure at the outlet port dropped below 20 psi, the relief valve would open. (See Figure 5-3.) - Paper filter elements are replaced on a scheduled basis, depending on the needs of the specific aircraft system. Replacing unscheduled filter elements is also required when certain components are removed. Never try to gage the condition of a filter by visual inspection alone.
Since the naked eye cannot detect particles smaller than 40 microns, an element could be heavily contaminated with 10- to 20-micron particles. The only way this condition could be determined would be by performing a back-pressure flow check on a test stand. Another danger of relying on visual inspection alone is that while filter elements may seem identical in outward appearance and in physical dimensions, they differ internally. For this reason, filters must always be identified by part numbers. Filters installed in the wrong fluid will go to pieces and cause major problems in the hydraulic system.
To remove and replace paper filter elements-- Relieve system pressure by operating the main system bypass valve or by actuating a hydraulically operated unit. Depressurize reservoir (if necessary). 5 - 4