Downloaded from https://www.everyspec.com FM 1-509 Cut lockwire. Unscrew the filter case and remove it from the filter head using a slight rocking and downward pull on the case after the case threads are free from the filter. Extract the retaining ring and remove the filter element from the case. Cut the filter element after ensuring that a replacement filter element is available, and inspect it internally for evidence of system contamination. Before installing the new filter, clean the filter head and case, and inspect them for damage; replace all damaged parts. Replace all O-ring packings. Fill the filter bowl with new fluid before attaching it to the filter housing head.
Filling the bowl helps to stop the injection of air into the system. Install the filter in its case, and screw the case into the filter head. The correct torque is usually hand-tight plus one-eighth of a turn, but always check the appropriate maintenance manual for the specific torque value. Pressurize the hydraulic system, and inspect the filter assembly for leaks. If the assembly is satisfactory, replace the lockwire between the filter case and head assembly. Fluid Filters With Stainless Steel Elements. Stainless steel filter elements are used in most modern aircraft. Filter element surfaces of this type usually have a corrugated stainless steel mesh construction.
Such filters are usually rated from 5- to 10-micron nominal flow and 25-micron absolute flow. This means about 95 percent of 5- to 10-micron particles and 100 percent of 25-micron particles will be filtered from the fluid. The curved passages of the filter element limit the length of the particles that pass through the filter. Filters with a differential pressure indicator (Figure 5-4) operate on the difference between the pressure entering the element and the pressure after it leaves the element. When contaminating particles collect on the outside of the filter element, the differential pressure across the element increases.
When this increased pressure reaches a specific value, inlet pressure forces the spring-loaded magnetic piston downward, breaking the magnetic attachment between the indicator button and the magnetic piston. This allows the red indicator on the differential pressure indicator to pop out, which indicates that the element must be cleaned. (See Figure 5-5.) Because increased fluid viscosity at low temperatures might cause a false indication of contamination, a low-temperature lockout of the differential pressure indicator prevents actuation at low temperatures. If the filter 5-5