Downloaded from https://www.everyspec.com FM 1-509 The piston-type pump uses case pressure for cooling and lubrication. Fluid seeps by the pistons in the cylinder block and fills all the space inside the pump. This fluid cannot escape through the drive end of the pump because of a seal around the drive shaft. Excess case pressure within the housing is routed back to the intake side of the pump through a relief valve called a foot valve. This valve prevents the case pressure from rising above approximately 15 psi. Drilled passageways through the universal link rods help to keep the rod ball ends lubricated.
In Figure 6-4, the foot valve (F) is located inside the bearing around which the cylinder block rotates. Other models have the valve in the head, along with the intake and outlet ports. Some of the newer models have two foot valves located in the head. The direction in which the accessory drive rotates determines the direction of pump action. An arrow on the pump head indicates the direction of rotation for which the pump is set up. The direction of rotation of a piston-type pump with one foot valve can be reversed. To reverse the direction, remove the cylinder block head, rotate 6-3