FM 1-509 Downloaded from https://www.everyspec.com it 180°, and reinstall it. Leave suction and pressure attachments as they were. This, in effect, reverses the intake and outlet port slots. It is not necessary to rotate the head on models with two foot valves; simply interchange the suction and pressure-line connections. Variable-Volume Pumps. Variable-volume pumps have some advantages. One advantage is that they do away with a pressure regulator or an unloading valve; integral flow control valves regulate the pressure according to the demands made on the system. A second advantage is that pressure surges are reduced.
Accumulators are not needed to smooth out surges with systems using variable-volume pumps; they are retained to aid the pump when peak loads occur. There are three types of variable-volume pumps. Stratopower effective stroke pump (variable-volume). Figure 6-5 illustrates a full-flow stratopower pump. The drive shaft (F) rotates the cam (D). This cam causes the nine spring-loaded pistons (G) to move back and forth in their cylinders, which are in a stationary cylinder block. In operation, each piston is forced into and removed from the cylinder once for each revolution of the cam.
The pistons are held in contact with the cam by piston springs which also return the pistons after each forward or power stroke. Each piston has a half-ball-bearing surface which acts like a universal linkage. The flat side contacts the cam during all angle changes. The pistons have fairly large hollow centers, connected with 6-4