Downloaded from https://www.everyspec.com FM 1-509 builds up any pressure, the yoke is held by the spring in the pressure-control piston (L) in the position shown in the full-flow illustration. (See Figure 6-7.) As the pressure in the system starts to drop, its force on the pilot valve is reduced. When this happens, the spring under the pilot valve moves the pressure upward. This reduces the opening to the passageway and cuts down the pressure on the pressure-control piston so that its spring pushes it to the right. Now the yoke swivels downward, causing the stroke of the pistons to increase. The pressure and volume output again start to increase until the system’s demands are met.
This action of the pressure-control valve (H) stabilizes the position of the cylinder block (D); its angle adjusts to meet the system’s demands. Notice that the hollow center of the pressure-control piston is vented to the inside of the case (M) so that fluid trapped inside the piston can escape to the case. A foot valve (not shown) prevents case pressure from becoming too high. The direction of the pump’s rotation cannot be changed. Therefore, you must be sure to check the direction arrow on the mounting flange before installing the pump. Pressure is increased or decreased by turning the adjusting screw (K).
An internal relief valve prevents damage in case the pressure-control valve fails to function properly. As long as there is no pressure in the system, the cylinder block and yoke are in the extreme angle position. (See Figure 6-8.) System pressure 6-7