everyspec.com hydraulic manual — Chapter 6 - Hydraulic Pumps and Motors

Downloaded from https://www.everyspec.com FM 1-509 entering the connecting line (G) acts on the pilot valve (J), pushing it down against the spring toward the zero-flow position. This opens the passageway (F), sending pressure against the rod side of the pressure- control piston (L). As the piston moves to the left, its spring is compressed. This force, which is transmitted through the valve plate (E), causes the yoke to swivel upward so that the cylinder block moves toward a zero angle. If the cylinder block reaches the extreme zero-flow point, there is no fluid output to the system.

This is because the pistons have no stroke in the cylinder block; they simply rotate with the cylinder block without moving back and forth. Kellogg stroke-reduction pump (variabl e-volume). (See Figure 6-9.) The Kellogg pump consists of of two major component groups: the rotating group and the pressure-compensating group The rotating group consists of the drive shaft (E), cylinder barrel (B), and nine pistons (C) with their piston shoes and locking plates (D). The pressure-compensating group consists of a cam plate (F), a compensator valve (G), and a control piston (H). The cylinder barrel is supported in the housing by a roller bearing (A).

The drive shaft passes through--but does not touch--the inclined cam plate to rotate the cylinder barrel unit. Pistons of the rotating group are actuated by tilting the nonrotating cam plate. The contact is a universal-action type consisting of hydraulically balanced shoes and locking plates. The length of the piston stroke is determined by the angle of the cam plate. Maximum pump output requires a high angle; zero pump output requires a flat angle setting. 6-8