everyspec.com hydraulic manual — Chapter 7 - Pressure-Regulating Devices

Downloaded from https://www.everyspec.com FM 1-509 pressure forces the piston (B) to depress the clear of the poppet valve. This action opens fluid flows through the valve into the return load spring (C) and to move the piston s passage, and line. When pressure at the pressure port is reduced to 3,190 psi, the coil spring reseats the piston against the poppet valve. This action stops the fluid from flowing through the relief valve. If the pressure at the outlet port exceeds the pressure at the inlet port, the poppet valve will unseat, and fluid from the return line will flow through the-valve into the pressure line. Thermal Relief Valve.

This relief valve is usually smaller than a main system relief valve. The thermal relief valve is used in systems where a check valve or a selector valve prevents pressure from being relieved through the main system relief valve. As pressurized fluid in the line builds up to an excessive amount, the valve poppet is forced off its seat, and the excess pressurized fluid flows through the relief valve to the reservoir. When system pressure decreases to a preset pressure, spring tension overcomes system pressure and forces the valve poppet to the closed position. 7-4