Downloaded from https://www.everyspec.com FM 1-509 Maintenance. Relief valve maintenance is limited to adjusting the valve to the correct pressure setting and checking it for leaks. If a relief valve is suspected of leaking-internally, connect a flexible hose to the return port of the valve; any drippings can be caught in a container. The opening and closing pressure of the valve may also be checked in this manner if an external power source is used. CAUTION DO NOT ATTEMPT TO ADJUST A RELIEF VALVE WHILE IT IS INSTALLED ON AN AIRCRAFT. REMOVE AND ADJUST THE VALVE ON A TEST STAND. THE SAME RULE APPLIES TO ALL RELIEF VALVES:
TURN THE ADJUSTING SCREW CLOCKWISE TO INCREASE OPENING PRESSURE AND COUNTERCLOCKWISE TO DECREASE OPENING PRESSURE. PRESSURE-REDUCING VALVES Purpose. A pressure-reducing valve (Figure 7-4) is used in hydraulic systems to lower the normal system operating pressure to a specified amount. It also acts as a relief valve. Operation. In Figure 7-4, system pressure is being ported to a subsystem through the shuttle and sleeve assembly. Subsystem pressurized fluid works on the large flange area of the shuttle, causing it to move to the left after reaching a set pressure and closing off the normal system. The valve will stay in this position until subsystem pressure is lowered.
The shuttle will then move to its prior position, allowing the required amount of pressurized fluid to enter the subsystem. During the normal operation of the subsystem, the pressure-reducing valve continuously meters fluid to the system. When pressurized fluid builds up to an excess amount within the subsystem, the shuttle assembly overcomes spring tension and 7-5