Downloaded from https://www.everyspec.com FM 1-509 Cylindrical Accumulator. The cylindrical accumulator consists of a cylinder and piston assembly. (See Figure 7-6.) Caps are attached to both ends of the cylinder. The internal piston separates the fluid chamber from the air (or nitrogen) chamber. The end caps and the piston are sealed by gaskets and packings. These sealants prevent external leakage around the caps and internal leakage between the chambers. A hydraulic fitting in the end cap on the fluid side attaches the fluid chamber to the hydraulic system. An air filler valve in the other end performs the same function as the air filler valve in the spherical accumulator. Operation.
Spherical and cylindrical accumulators operate essentially the same. In operation, the compressed-air chamber is charged to a set pressure somewhat lower than the system operating pressure. This initial charge is known as the accumulator preload. To illustrate the operation of the accumulator, let us assume that the cylindrical accumulator shown in Figure 7-6 is designed for a preload of 1,300 psi in a 3,000-psi system. When the initial charge of 1,300 psi is introduced into the unit, hydraulic system pressure is zero. As air pressure is applied through the air pressure port, it moves the piston toward the opposite end until it bottoms.
If the air behind the piston has a pressure of 1,300 psi, the hydraulic system pump will have to create a pressure within the system greater than 1,300 psi before the hydraulic fluid can actuate the piston. At 1,301 psi, the piston will start to move within the cylinder, compressing the air as it moves. At 2,000 psi, it will have backed up several inches. At 3,000 psi, the piston will have backed up to its normal operating position, compressing the air until it occupies a space less than one-half of the cylinder’s length. When hydraulic units lower system pressure, the compressed air causes the piston to move, forcing fluid from the accumulator and supplying fluid to the hydraulic system.
Maintenance. Examine accumulators visually for external hydraulic fluid leaks. To find an external air leak, brush the exterior with soapy water; bubbles will form wherever air is leaking. To find an internal leak, loosen the air valve assembly. If hydraulic fluid comes out of the air valve, remove and replace the accumulator. 7-7