Downloaded from https://www.everyspec.com MIL-HDBK-310 5.1.19 Low Atmospheric Density. The lowest density to which ground military equipment may be subjected is a function primarily of altitude. As discussed in Section 5.1.17, the highest altitude contemplated for military operations is 4572 m. low density extremes for this and lower elevations are presented in this section. Low air density greatly affects aircraft aerodynamic and engine performance. The density of the air near the ground is especially important in aircraft design since the lower the density, the longer the takeoff roll required by fixed-wing aircraft and the less weight a rotary-wing aircraft can lift.
Concurrent temperature also has an important secondary effect and is necessary for a thorough analysis of engine performance. 5.1.19.1 Lowest Recorded. Not available. 5.1.19.2 Frequency of Occurrence. Based on the assumption that low density extremes for a given elevation will occur during extremes of high temperature, 48 stations representing different hot regions of the world and elevations from 3 to 4497 m were selected for study from various climatological tables. The 1-, 5-, 10-, and 20-percentile densities for each station/month and associated mean temperatures were plotted as a function of station elevation and examined for internal consistency.
Based on this analysis, the 1-percent density values and accompanying typical temperatures are: The 5-, 10-, and 20-percent values are in Table VIII (page 79). 5.1.19.3 Long-term Extremes. Not available. 5.1.20 Ozone Concentration. Accurate ozone measurement is more difficult than for most atmospheric elements, as might be expected for a gas that is usually present in concentrations of less than 1 part per million (ppm) and is also highly reactive. Frequent calibration of instruments is very important to assure accurate observations. Ozone measurements are expressed in two types of units: (1) mixing ratios and (2) concentration per unit volume.
The mixing ratio is an expression of the amount of ozone in a given amount of air, if both are in the same units. The concentration per unit volume gives the mass of ozone in a given volume of air. These units can be related, but the conversion factors vary with changes in pressure and temperature. For example, a mixing ratio of 1 ppm is equivalent to a concentration of 2.14 X 10 3 µ g/m 3 at 1 atmosphere (1.013 X 10 5 pascals or 1013 mb) pressure, whereas 1 ppm equals only about 1.07 X 10 3 µ g /m 3 at .5 atmosphere (.51 X 10 5 pa or 507 mb) pressure.
23 ELEVATION DENSITY TEMPERATURES (m) (ft) (kg/m3) (lb/ft3) (°C) (°F) 0 305 914 1524 2134 2743 3353 3962 4572 0 1000 3000 5000 7000 9000 11000 13000 15000 1.078 1.047 0.986 0.929 0.878 0.833 0.790 0.748 0.707 0.0673 0.0657 0.0616 0.0580 0.0548 0.0520 0.0493 0.0467 0.0441 47 47 44 40 36 31 26 20 17 117 117 111 104 97 88 79 68 63