Downloaded from https://www.everyspec.com MIL-HDBK-lool/2 G 2.5.2 Semipermanent Construction. Buildings and facilities designed and constructed to serve a specific purpose over a life expectancy of more than 5 yeara but less than 25 years should be energy efficient and noncombustible. Select finishes, materials, and systems for reasonable maintenance and life cycle costs based on 15 years. 2.5.3 Temporary Construction. It is defined as buildings and facilities designed and constructed to serve a specific purpose over a life expectancy of 5 years. Select ordinary construction, finishes, materials, and sYstems without maintenance costs being the primary factor. 2.5.4 Mobilization Construction.
Buildings and facilities, designed and constructed to serve a specific purpose for a life expectancy of 5 years or less under mobilization conditions, should be suitable for rapid erection utilizing conventional or industrialized construction techniques or both. Select austere finishes, materials, and systems without regard to maintenance costs . 2.6 Miscellaneous Selection Criteria. 2.6.1 maY offer Geographical Factors. Local and indigenous choices for creative uses of products. The materials and elements Ievel of local construction technology must also be considered.
Complicated industrialized curtain wall glazing systems would not be appropriate, for instance, in areas where construction technology is not advanced. G 2.6.2 Availabilit~. Products must be easily and quickly obtainable for initial construction. In addition, the future availability of the product for maintenance and replacement should be considered. Stock items should be used in lietiof special items where possible. 2.6.3 Energy Conservation. Energy conservation measures designed for the project will be a key influence on materials selection. Exterior wall and roof systems and materials must be chosen to maximize insulation values. 2.6.4 Acoustical Control.
NAVFAC DM--1.03, Architectural Acoustics, contains specific criteria for acoustical control through materials usage. It should be reviewed in the initial planning and design stages to aid in the selection of materials with the most effective acoustical properties. 2.6.5 Expansion. Building components and materials should accommodate expanaion. Systems and materials should be easily added to, enlarged, and readily available and reproducible. 2.6.6 Flexibility. Similar materials and finishes throughout a building will permit various functions to occur in ,different rooms.
Where undefined future functions or flexible usage is required, temporary or nonpermanent materials and construction should be considered.