Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 reasons : first, drilling holes in the yoke will destroy its magnetic symmetry; and, second, the iron between the positive and negative leads forms a magnetic core for a current loop. To avoid these problems, the armature leads, as well as any other leads, should be taken out through the nonmagnetic end bells of the machine The general rules for arrangement of conductors are as follows:
(a) Never arrange conductors and magnetic materials in such a way that the magnetic material forms a core for a current loop unless this arrangement is dictated by the necessity of designing equipment so that it will perform its intended function. (b) If it is absolutely necessary to pass a circuit through a magnetic enclosure or other magnetic material, the plus and minus legs of the circuit must be as close together as possible and both must pass through the same hole in the magnetic material.
(c) Care must be taken in the arrangement of conductors and magnetic material to avoid any possibility that the magnetic material will cause an unnecessary increase in the stray magnetic field generated by the current in the conductors (see 3.3.2.2). 5.12 Principle of final check. 5.12.1 Need for final check. The principles that have been discussed so far are guidelines that muse be followed in order to design and construct a piece of equipment having a small stray magnetic field. They do not, however, automati- cally ensure that the stray magnetic field will be small.
For example, the principle of zero net magnetic moment can be applied to the entire space occupied by a piece of equipment and to each of a large number of smaller regions into which this space can be subdivided, and still have a stray magnetic field that is too large to be acceptable (see 5.5.2), This possibility requires that a final check be made after a tentative design is completed. The design should be rejected unless it checks out satisfactorily. 5 12.2 Nature of the check.
Ideally, the check calculations should be so complete and accurate that they give an estimated value for the stray magnetic field to within a few percent of the values that would be measured if the equipment were built and tested. This goal should be attainable for relatively simple equipment which has no magnetic material used in its construction, but may not be attainable for complicated equipment, particularly for equipment in which magnetic material is used. For such equipment, a somewhat simplified check will have to be used. This will involve a check made without taking into account the effect of iron, followed by the best estimate that can be made OIL the effect of the iron.
The steps in detail are as follows: (a) First make a careful analysis of the complete equipment to resolve it into all the current loops it contains. This step is basic to all the rest. (b) If a suitable computer is available for use, compute the vertical component of magnetic field produced by each current loop at a specified point on a plane at the desired distance below the equipment, and add the results for the different loops to find the total for the whole equipment. The stray magnetic field from each loop must be calculated to many significant figures in order to