Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 give an algebraic sum which will be accurate to a few significant figures. The large volume of calculations makes calculation without the use of a computer impractical. (c) If a suitable computer is not available, the check will have to be made using a simpler method, as follows: 1. Divide the total nunber of current loops into a number of subgroups, each subgroup containing two, four, six, of eight loops of equal magnetic moment with a symmetrical arrangement and polarity so as to give a small magnetic field.

This can always be done for equipment that has been designed with opposing current loops so that the net magnetic moment is zero. If the net magnetic moment is almost but not quite equal to zero, it should be possible to proceed this way: Suppose that there are four loops symmetrically arranged, and make an array like that of 4.3.3.10, except that the magnetic moments are 100, -100, 100, and -95 instead of -100 for the loops. At the -95 loop acid two hypothetical loops, one with a magnetic moment of +5 and one with a magnetic moment of -5. Now divide all the loops into two subgroups:

one consisting of a symmetrical array of four loops with magnetic moments of 100, -100, 100, -100, and the other consisting of a single loop of magnetic moment +5 . In one way or another, the complete group of loops in the equivalent can be broken down into a number of subgroups. 2. Compute the maximum value of the vertical component of magnetic field produced by each subgroup of current loops. This can be done using the formulas of 4.3 or, if necessary, by deriving new formulas for subgroups of a kind not covered by 4.3. 3.

Suppose, to be specific, that there are six subgroups and that the maximum values of vertical component of magnetic field BZ5, and (without regard to algebraic sign) are Bzl, BZ2, BZ3, BZ4, BZ6. The worst possible case would be for all six maxima to occur at the same place and to have the same sign. In this case, the magnitude of the total stray magnetic field would be: If this value is small enough to be acceptable, the design can be considered satisfactory. 4. If the value computed above is too large to be acceptable, it does not mean that the design is unsatisfactory.

It may be that the maxima for the different subgroups occur at fairly widely spaced locations, or that some of the maxima are of a different algebraic sign than others. It is very likely that the correct value for the maximum for the whole equipment will be less than the sum of the absolute values of the maxima of the subgroups, and may even be less than the maximum for any one of the subgroups. This possibility should be checked before concluding that the design is unsatisfactory. 5. If a careful check shows that the calculated value of stray magnetic field is too large to be acceptable, the design should 81