Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 6.2 Cable runs. We will consider the arrangement of power cables so that we may reduce to a minimum the stray magnetic field produced by the current in these cables. The design considerations discussed herein are applicable to shipboard installation of dc and alternating current (at) power cables aboard minesweepers and other special installations where stray magnetic fields must be reduced to a minimum 6.2.1 Cable runs modeled by current loops. Suppose we have a long cable run from a generator to a motor that consists of a single conductor cable in the positive leg and a single conductor cable in the negative leg.
We can model the cable run by current loops (see figure 45). If we introduce hypothetical conductors between A and B and between C and D, we break the cable run into a small current loop from the generator to AB, a long current loop from AB to CD, and a small current loop from CD to the motor. The design considerations for cable runs should govern the long current loop from AB to CD. 6.2.1.1 Single current loop. With only one single-conductor cable in the positive and negative legs of the long cable run discussed in 6.2.1, there will be only one current loop.
This will not be a small current loop (see 4.5) since the distance to the point where we are interested in the magnetic field may be less than the length, or large dimension, of the cable run. The magnetic field of the current loop can be calculated by using the formulas for large loops (see 4.2.2). Even if the cables forming the single current loop cable run are placed tightly together so that the geometric interior of the current loop has no area, the stray magnetic field can be appreciable. FIGURE 45. Current loops in cable runs. 6.2.1.2 Mulitiple current loops.
Minesweeping currents are so large that two or more single conductor cables are used in each leg of a minesweeping cable run to provide adequate current-carrying capacity. With such an arrangement, the cable run will have two or more current loops Depending upon how the cables are connected, the magnetic fields from these loops will add or subtract. 6.2.2 Power cables and cable configurations. Power cables and cable configurations will be in accordance with 6.2.2.1 through 6.2.2.2.2. 6,2.2.1 Dc power cables. Design considerations for dc power cables will be in accordance with 6.2.2.1.1 through 6.2.2.1.5. 6.2.2.1.1 Use of single-conductor cables.
For best results, we will use an even mulitple of parallel, single-conductor cables in the positive and negative branches of a dc cable. Quadded cables consisting of four single-conductor cables 83