NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 6 4.6 Shunt box. The design considerations for shunt box connections will be in accordance with 6.4.6.1 through 6.4.6.3. 6.4.6.1 Description of connection. Consider the problem that arises if we have to connect an ammeter shunt in a minesweeping cable run. An obvious solution is to cut the two positive cables, connect the shunt in the cut, and spread the two negative cables so that one goes around each side of the shunt (see figure 63).

For a more elaborate arrangement, put the shunt in a box with three terminals sticking out of each end of the box for connection to the cable runs This shunt box is a simple example of three-terminal equipment that evolves naturally out of the quad cable run. 6.4.6.2 Current loops. The current loops associated with the shunt box (see figure 63) are divided into three groups as follows: (a) Loops A, B, I, and J are caused by the cable runs to and from the shunt box. (b) Loops C, D, G, and H start where the cables depart from the quad array and end where connections are made to the terminals, T, of the box. These loops are caused by the connection between the cable run and the box.

(c) Loops E and F are caused by the components and bus work in the box itself. 104