Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 6.5.2.2 Advantages of the form. The small stray magnetic field form will have a much smaller field than the typical induction clutch design for the following two reasons: (a) First, each of the small field coils in the small stray magnetic field form will have a much smaller magnetic moment than the single field coil in the typical induction clutch design. This will give us a smaller stray magnetic field. (b) Second, and even more important, is the large number of poles.
If we take coils uniformly spaced on a circle of radius R with coils alternately north and south, the stray magnetic field at a distance decreases as the number of poles increases, even when the radius of the circle and the magnetic moments of the individual coils remain the same. The induction clutch will have a considerable number of field coils, probably sixteen or more. With so many field coils, the stray magnetic field will be small 7. DESIGN OF MINESWEEPING GENERATORS 7.1 General. 7.1.1 Introduction. Strong magnetic fields inside a dc motor or generator are essential for the operation of the machine.
These magnetic fields, being inside the machine, obviously cannot affect a magnetic mine outside the machine and are not a source of danger. What is dangerous, so far as magnetic nines are concerned, is the external magnetic field or the stray magnetic field outside the machine. This is the difference between the magnetic field when current is flowing and when current is not flowing in any circuit or part of the machine. This stray magnetic field is zero when all currents are zero. Its magnitude, when currents are flowing, depends upon the magnitudes of currents and the nature of the particular circuits in which they are flowing. 7.1.1.1 Desire objectives.
Depending upon the size and design of a machine, its external or stray magnetic field may be either relatively large or quite small; large enough to actuate a mine many feet from the machine or small enough to be undetected by a mine quite close to the machine. One of the primary objectives in designing a minesweeping generator is to make the stray magnetic field as small as possible. 7.1.1.2 Application to machines other than minesweeeping generators. The discussion in this paragraph is specifically in terms of the design of minesweeping generators.
These must be designed with the greatest of care because they are large machines and are used in minesweepers that may pass directly over magnetic mines. Therefore, they must produce only the smallest stray magnetic field possible in order to minimize the danger of firing a mine under the minesweeper. Note, however, that the same principles must be used in the design of any \ motor or generator for which small stray magnetic field is an important consideration. 119