NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 7.1.2 Cause of stray magnetic field. Electric current is the cause of stray magnetic field. In a minesweeping generator there are two principal circuits, the field circuit and the armature circuit. Current in either one or in both can give rise to stray magnetic field. Both must be designed to make this effect. as small as possible. The field circuit is considered in 7.2; the armature circuit, which carries a much larger current, in 7.3. 7.1.3 Essential features in generator desire.

Theoretical studies show that there are certain essential features that must be incorporated in minesweeping generators designed for minimum stray magnetic field. The necessity for some of these features has been amply verified by experience. The necessity for others has not yet been tested by experience but is firmly based upon theoretical studies. The essential features are listed below. Details concerning them and the reasons why they are essential are given in the rest of this section in the paragraphs to which references are given. 7.1.3.1 Frame. Minesweeping generator frames will have the following features:

(a) The frame will be either solid, with no joints, or laminated (see 7.2.3.4 (a)) (b) The weld in the frame will be at a main pole (see 7.2.3.4 (b)). (c) The frame will be machined inside and outside, to ensure uniform cross section throughout (see 7.2.3.4 (c)). (d) The material of the frame will be magnetically homogeneous throughout (see 7.2.3.4 (d)). (e) The outside of the magnetic material in the frame will be, as nearly as possible, a smooth surface of revolution with its axis coincident with the axis of the generator. There will be no magnetic feet or other major projections of magnetic material on the outside of the frame (see 7.2.3.4 (e)).

(f) Current carrying leads are not to be taken through the frame. They will go through some part of the generator enclosure that is nonmagnetic (see 7.2.3.4 (f)). 7.1.3.2 Number of field poles. The machine must have an adequate number of field poles in accordance with 7.2.3.5 and 7.2.3.6. 7.1.3.3 Symmetry and uniformity. The following aspects of symmetry and uniformity will be applied: (a) Air gaps will be uniform (see 7.2.3.4 (g)) - (b) In machines that have commutating poles, there will be as many commutating poles as main poles (see 7.2.3.4 (h)).

(c) Coils of the same type, such as shunt field coils and commutating pole coils, will be of the same size and have exactly the same number of turns (see 7.2.3.4 (i)). 7.1.3.4 Wiring around the frame Wiring around the frame will have the following features: 120