NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 7.1.4.1 Angular position of takeoff Points. It is probably better to have the takeoff point from one brush collector ring at the same point where one set of brushes is connected to the ring (see 7.3.2.29). 7.1.4.2 Number of commutator bars. It is better to have the number of commutator bars equal to an integral multiple of the number of poles (see 7.3.2.30). 7 1 4.3 Brush rigging. The brush rigging should be so designed as to force a well-defined current path from a set of brushes to the brush collector ring.

It will be desirable for this current path to be in a plane that passes through the axis of the machine (see 7.3.2.28) 7.1.4.4 Position of brush collector rings. The axial distance from the brush collector rings to the commutator risers should be so chosen as to minimize the effect of unequal current division between different sets of brushes (see 7.3.2.28). 7.2 Field circuit design. 7.2.1 Appliability. Minesweeping generators are separately-excited machines. The following discussion will, therefore, be specifically in terms of the field circuit for a separately excited machine. Note, however, that similar considerations apply to the shunt field circuit of a shunt-wound motor or generator.

7.2.2 Sources of stray magnetic field. The field circuit consists of two separate stray magnetic field sources: the field coils and the connections to the field coils. Design guidelines to minimize the stray magnetic field produced by the field coils are described in 7.2.3.1 through 7.2.3.5. The design guidelines to minimize the stray magnetic field produced by connections to the field coils are described in 7.2.3. 7.2.3 Minimization of stray magnetic field produced by the field coils. The field coils set up the useful or working flux that is essential for the operation of the generator.

In a large generator, the field coils are of respectable size, have a considerable number of turns, and carry an appreciable field current. One field coil alone will set up a stray magnetic field that is larger than can be tolerated for a minesweeping generator. All field coils together set up a stray magnetic field that is smaller (except for a two-pole machine) than the stray magnetic field from a single coil. We will use the term ‘polar leakage field" to designate the stray magnetic field that is set up by the field coils alone The polar leakage field depends upon the following: (a) The magnetic moment of each field coil. (b) The number and orientation of the field coils.

(c) The distance from the field coils to the center of the machine. (d) The effect of iron in the machine. (e) The effect of nonuniformity in pole strengths, air gaps, and magnetic circuit. 122