NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 7.2.3.1 Number and orientation of field coils. In order to avoid the consideration of the effect of iron, consider four sets of coils; one each with two, four, six, and eight coils held in nonmagnetic supports in the position that they would occupy in two-, four-, six-, and eight-pole generators with one pair of poles arranged vertically. Let us also compare these to a single coil. The five arrays are shown on figure 73, where each coil is represented by a short arrow in the direction of the coil’s magnetic moment.

Assume that the magnetic moment of each coil is 93 square meter ampere turns (1000 square foot ampere turns) and that each set of coils is arranged in a circle with a radius of 0,3 meter (1 foot). From the formula given in 4.3, the maximum values of the vertical component of magnetic field, in nanotesla, for distances 6, 9, and 12 meters (20, 30, and 40 feet) below the center of the arrays will be as shown in table VII. TABLE VII. Magnetic field values of coils with a constant magnetic moment. 123