Downloaded from https://www.everyspec.com FIGURE 79. End view showing currents in the current loops of the armature winding. 7.3.2.9 Effect of equalizer connections. So far, we have been considering a lap wound armature without equalizer connections, which are also known as armature cross connections. An actual lap wound armature will have equalizer connection in the form of conduction rings at the front or back end of the armature winding. One ring is connected to all points on the armature winding that are theoretically at the same potential, zero potential, for example. Another ring is connected to all points that are 20 volts above the zero potential, and so on.
In an ideal machine, these equalizer connections would be unnecessary, as all the pole strengths end brush resistances would be exactly equal. However, this ideal, highly symmetrical machine would be all but impossible to realize. We will therefore, use two simplified cases to illustrate the effect of equalizer connections on practical machines. These two cases are as follows: (a) A machine that is completely symmetrical except that the field poles are not of exactly equal strength. (b) A machine that is completely symmetrical except that the brush resistances are unequal. For the first case let us again consider a four pole machine.
If the pole strengths are not exactly equal, the voltages induced in the four quarters of the armature winding will not be equal and the four brush currents will not be equal, even though the brush resistances are all equal. Now let us add equalizer connections. In machines designed and built for small stray magnetic fields, the equalizer connections should be complete rings. of uniform cross sections, concentric to the shaft, which are connected to the appropriate points on the armature.
The equalizing connections provide current paths for alternating currents that flow in such direction as to magnetize the weak poles, demagnetize the strong poles, and equalize the flux distribution and induced voltages around the machine. Although they cannot give perfect equalization, since this would reduce the induced voltages that cause current to flow in them to zero, equalizing connections are highly effective, as shown by the following two examples reported in the technical literature. In one case, d fourteen-pole generator with equalized armature operated reasonably well for several months before it was discovered that two of the main field-poles were reversed. The equalizer 137