Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 connections had equalized the flux distribution to permit operation of the machine. In the other case, one of the bearings on a generator slipped, allowing the armature to almost touch the field poles. With the equalized armature that was on this generator, there was no evidence of magnetic pull or unbalancing, except possibly a slight sparking at the commutator. We can conclude, therefore, that with an equalized armature winding, inequalities of field pole strength will be almost completely neutralized. Let us now consider a four-pole generator with exactly equal pole strengths but unequal brush resistances.

This will cause the brush currents to be unequal We can see this most easily by assuming that one of the two positive brush sets is completely disconnected. We then have one of the positive brush sets taking full output current while the other positive brush set takes none. Obviously, the equalizer connections on the armature car, do nothing to change this situation. Therefore, we see that while the equalizer connections can equalize the flux distribution and generated voltages, they cannot ensure equality of current division between the brush sets. It remains, therefore, to consider the effect that this inequality of current division will have.

For a nonequalized armature winding, we have already seen (7.3.2.8) that the four loops in the armature winding will have a net magnetic moment different from zero when the brush currents are not equal in magnitude. This net magnetic moment will give rise to a stray magnetic field. Now consider an equalized armature winding. Suppose first that the field poles are exactly equal strength N, S } N, S. Now suppose that one N pole is made a little stronger and that the diametrically opposite N pole is made weaker by the same amount. This gives N+n, S, N-n, S. We see that this is the superposition of four poles of O.

The function of the equalizer winding is to permit alternating currents to flow in such direction as to eliminate the two-pole field and replace it with the four-pole field, This is what the equalizing winding does when an initially symmetrical four-pole field is distorted by the superposition of a two-pole field caused by strengthening one N pole and weakening the diametrically opposite N pole.

Now consider this situation Suppose we cut off the shunt field current, drive the armature at rated speed, lift the negative brushes, and from an external source, send current into the armature through one of the positive brush sets and take it away through the other positive brush sets (that would have to be reconnected to do this). The current through the armature will set up a two-pole field. Even though the armature is rotating, the two-pole field it creates will be stationary in space, just as the armature reaction of any dc armature is stationary in space.

The situation thus appears to be precisely the same as if the two-pole field were set up by strengthening one field pole and weakening the diametrically opposite pole. The equalizer connections equalize such a two-pole field; they should also equalize fields caused by current in the armature . We conclude, therefore that with an equalized armature, the four-pole armature will set up a field with N, S, N, S poles of very nearly equal strength and the net magnetic moment of the four loops of the armature will be very nearly equal to zero regardless of whether the brush currents are equal or not. 7.3.2.10 Wave windings.

We have considered up to now only lap wound armatures , initially without and then with equalizer connections. Wave wound armatures have no equalizer connections because the winding itself functions as an equalizer. It would appear, therefore, that a wave winding will act in the same way as a lap winding so far as stray magnetic field is concerned. 138