NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 7.3.2.11 Symmetry. One of the simplifying assumptions (see 7.3.2.1) was that the number of commutator bars is an integral multiple of the number of poles. This condition is obviously necessary to give a completely symmetrical machine. It can be satisfied by lap windings, but not by wave windings, for a machine with four or more poles. In the interest of symmetry, therefore, it would be preferable to use a lap wound armature having a number of commutator bars equal to an integral multiple of the number of poles.

We do not know how much difference in stray magnetic field there will be between two generators that are identical except that the armature of one has a number of commutator bars equal to an integral multiple of number of poles, while the armature of the other does not. It may be that the difference is too small to be appreciable, but in light of our present knowledge, it would appear that the advantage will be with the machine for which this condition is satisfied. 7.3.2.12 Need for uniformity of construction.

It might appear from the preceding discussion that we can build a machine without taking pains to have poles of equal strength and leave it to the equalizer connections to equalize the pole strengths. It may be that we can do this without paying any penalty in greater stray magnetic field than from a machine carefully built to have poles of equal strength. As of now, however, we do not know that we can. We have no experimental tests to prove that inequality of pole strength does not increase stray magnetic field if the armature has equalizer connections.

Until we have such proof, we must have our minesweeping generators built with extreme care to ensure equal pole strength, Even so, there will be unavoidable deviations from exact quality, effects. and the equalizer connections must be relied upon to minimize their 7.3.2.13 Summary of current loops in the armature winding. (a) The equalizer connections will cause the current loops in the armature winding to be very nearly equal in strength regardless of whether the brush currents are equal or not. Such equal current loops, at least eight or more in a minesweeping (b) generator, will give a small stray magnetic field. Most minesweeping generators have a compensating or pole-face (c) winding.

This is wound in slots in the pole faces, carries armature current, and produces a magnetic field that is opposed to that produced by current in the armature winding, The resultant field produced by both the armature winding and the pole-face winding should be very small. For these reasons, the armature winding and the currents in it should not be a major source of stray magnetic field. This is fortunate as it is not immediately apparent how they could be changed, The construction of the armature with the armature winding, commutator, and commutator risers is dictated by the necessity of having a generator chat will function properly. (d) The rest of the armature circuit.

Let us now turn our attention to of figure 77. As pointed out in 7.3.2.7 this is incomplete in that it does not show the commutator risers and the connections from the brushes to the brush collector rings. In order to bring these into view, let us change the lower part of figure 77 into the developed isometric drawing shown on figure 80. Here 7.3.2.14 the lower part 139