NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 7.3.3.4 Connections for concentric two-brush collector ring construction. Figure 100 is an example of connections that could be used for a machine with two concentric brush collector rings. It is apparent that this arrangement can be readily adapted for use on a machine with three-brush collector rings. FIGURE 100. Connections for a machine with two concentric brush collector rings. 7.3.3.5 Terminals. The machine should have either of the following:

(a) Four terminals arranged at the comers of a square with positive terminals at the ends of one diagonal and negative terminals at the ends of the outer diagonal; or (b) Three terminals equally spaced along a line with a positive (or negative) terminal at the center and two negative (or positive) terminals on the outside. With the four-terminal arrangement there is one terminal for connection to each of the cables in the quadded minesweeping cable run. With the three-terminal arrangement, two diagonally opposite cables in the cable run are connected to the center terminal; the other two cables are connected to the outside terminals (see 6 3.4) 165