Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 7 .3.3.6 Conditions for good desire. The designer has the problem of fitting to his machine connections that embody the principles illustrated on figures 99 and 100. After the design has been completed, it should be checked to see if it satisfies the following conditions. (a) The current loops are individually as small as they can be made, taking into account the physical dimensions of the conductors and the necessity of spacing to provide room for insulation.
(b) For each current loop there is in the same plane an immediately adjacent loop, which is as close as possible to the first loop, and of the same magnetic moment but opposite polarity. (c) Parallel circuits are and will remain of equal resistance to ensure equal division of current between the circuits. Unless all of these conditions are satisfied, the design is not as good as it should be, If all are satisfied, the design is as good as possible. 7.4 Commutating pole or interpole winding. 7.4.1 General. Commutating poles are used to improve commutation. They are located midway between the main field poles and are frequently referred to as interposes .
Some dc generators have interposes but no compensating or pole-face winding. This was the case for all of our World War II minesweeping generators and is also the case for a few of the minesweeping generators built for the minesweepers of today. Other dc generators have interposes and a compensating or pole-face winding as well. This is the case for most minesweeping generators built for the minesweepers of today. Current in the interpole circuit is through the interpole coils and the connections to the coils.
The coils themselves (see 7.4.2) produce only a small stray magnetic field; hence, the problem involved in the design of an interpole circuit is to arrange the connections so that they also will produce only a small stray magnetic field. On figures 101 to 102, the interpole circuit is shown completely closed on itself. It is tied into the rest of the armature circuit by cutting one of the connections between coils and connecting to the brush collector rings and terminals at the points marked “CONNECTION TO COMMUTATING POLES AND COMPENSATING WINDING" on figures 99 (A) and 100. Only the interpoles are shown on figures 101 to 103.
The main poles are omitted because they are not connected in the interpole circuit. FIGURE 101. Very bad arrangement of connections to interpol es , 166