Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 7.5.4.3 Series circuit winding in odd number of slots. It may be possible to lay out a single series circuit compensating winding in such a way that the clockwise and counterclockwise angles will balance at each end, as was the case for the winding discussed in 7.5.3 for a machine with an even number of slots per pole face. Unfortunately, however, we do not yet know how to lay out such a winding and, moreover, it seems probable that this cannot be done.
Consequently, field is an important consideration, a in all cases where a small stray magnetic single compensating winding must not be used if the number of slots per pole is odd, 7.5.5 Winding for an odd number of slots per pole face. 7.5.5.1 Conditions for use. If possible, minesweeping generators should be designed with compensating windings in an even number of slots per pole face. If, however, the characteristics of the machine are such as to make an odd number of slots either indispensable or highly desirable, they can be used provided the number of poles is an integral multiple of four. 7.5.5.2 Example for an eight-pole machine.
An example of a suitable compensating winding for an eight-pole machine with three slots per pole face is shown on figure 106. There are two conductors per slot instead of only one (or several conductors in parallel) as in the windings discussed previously. The compensating winding has two parallel circuits, each of which carries only one- half the armature current. One parallel circuit is to the right of the vertical center line; the other is to the left. Connections to the leads that bring current to and take it from the parallel circuits are not shown but can be made on the vertical centerline where the two halves are close together.
Inspection of the figure and preparation of tables similar to tables XIV and XV will show that each half of the winding is balanced on itself at each end of the machine. Cancellation of magnetic fields is not dependent upon equality of current division between the halves and the stray magnetic field should be small. No machines with compensating windings like this have yet been tested for stray magnetic fields but the results should be good. This assumes, however, that the end connectors are arranged as close together as possible (see 7.5.6) 7.5.5.3 Extension to other cases.
Although the winding shown on figure 106 is for the specific case of an eight-pole machine with three slots per pole face, further consideration will show that the basic scheme can be used for any generator with eight poles and any odd number of slots per pole face. It can also be used for any odd number of slots and any number of poles that is an integral multiple of four If the number of poles is not an integral multiple of four, six poles for example, then each half of the compensating winding will not be completely balanced on itself.
For this reason, the basic scheme of the winding shown on figure 106 should not be used except for generators with four (too few for minesweeping generators), eight, twelve, or sixteen poles. 7.5.6 Loops in transverse Planes. The end connectors at each end of the machine will form loops in a plane perpendicular to the axis of the machine, These loops should be kept small by keeping the end connectors close together. Furthermore , these loops should have positive and negative magnetic moments so that the sum of the magnetic moments at each end of the machine is zero. 176